Who handles RenewAire?


TC7D
Digital Time Clock
  • Up to 8 on/off Cycles Per Day or 56 Per Week
  • 24VAC Power Requirement
  • Battery Back-Up
  • Wall Mount or Outdoor Enclosure Options
  • Wall Mount fits any 4" x 4" electric box
  • Optional RenewAire Transformer Relay Package May Be Used

MC
Motion (Occupancy) Control
  • Passive Infared Sensor
  • Adjustable Time-Off Delay to 30 Minutes
  • 24VAC Power Requirement
  • Ceiling Mount or Directable Wall Mount
  • Coversup to 1500 sq. ft. floor space
  • Requires the Use of RenewAire Transformer Relay Package (Ordered Separately)

CO2
Carbon Dioxide Control
  • Adjustable Control from 600-2000 PPM
  • Digital Display
  • 24VAC ower Requirement
  • Computer/BAS Interface for Information & Control
  • Self Calibrates During Periods of Low Occupancy
  • Wall Mount or Add Duct Mount Accessory
  • Requires the Use of RenewAire Transformer Relay Package (Ordered Separately)

DH24
Dehumidistat Control
  • Secondary Control To Time Clock or Other Primary Control
  • Mechanical Switching of 24VAC (or 120VAC)
  • Adjustable from 0 - 100% Relative Humidity
  • Wall Mount to Single Gang Box
  • Note: RenewAire ERVs are not to be used for applications where indoor relative humidity exceeds 50% RH for extended periods of time.

DS
Disconnect Switch
  • Fused or Non-fused
  • Indoor NEMA 3R Exterior Enclosures
  • Installation Voltage Must be Specified: 115, 208-230, 460
  • Installed on Unit and Wired to Unit Contactor

TR40
Transformer Relay Package
  • Provides a 24VAC, 40VA Class II Power Supply for Unit Control
  • Includes Isolation Relay with Low Voltage Circuit Breaker
  • Handles any RenewAire Unit with 1 Contactor
  • Installation Voltage Must be Specified: 115, 208-230, 460
  • Installed in Unit Electric Box
  • Available with 45CONT Contactor for EV456 Control Options (shipped loose)

IBC
Independent Blower Control
  • Adds a Second Contactor to Allow Independent Control of Exhaust Fan and Supply Fan
  • May Be Used to Provide Economizer (no heat recovery operation) Function
  • Can Provide Relief Fan or Make-up Air Function to Benefit Building Pressurization
  • Installed on a Unit Electrical Box
   
A participating Company in the ARI AIR-TO-AIR ENERGY RECOVERY VENTILATION EQUIPMENT Certification Program The world's leading residential ventilation manufacturers ensure customer satisfaction with HVI Certified Performance Ratings available exclusively thorughthe Home Ventilating Institute. For more information on HVI Certified Ventilation Performance, ventilation selection and design, indoor air quality and much more visit www.hvi.org.